Переглянути джерело

Conference timer should start counting at 0

It's starting at 1 hour because os.time(os.date("!*t") returns the wrong
time depending on system timezone. os.time() already returns the number
of seconds since epoch in UTC so just use that.

Fixes #5595
master
Ruben Kerkhof 5 роки тому
джерело
коміт
57bb2ead36

+ 1
- 1
resources/prosody-plugins/mod_conference_duration_component.lua Переглянути файл

@@ -28,7 +28,7 @@ function occupant_joined(event)
28 28
     if participant_count > 1 then
29 29
 
30 30
         if room.created_timestamp == nil then
31
-            room.created_timestamp = os.time(os.date("!*t")) * 1000; -- Lua provides UTC time in seconds, so convert to milliseconds
31
+            room.created_timestamp = os.time() * 1000; -- Lua provides UTC time in seconds, so convert to milliseconds
32 32
         end
33 33
 
34 34
         local body_json = {};

Завантаження…
Відмінити